WATER PROCESS DESCRIPTION

Raw water is chlorinated with the help of dosing pump, Sodium Hypo chloride is dosed in raw water before it is taken into the raw water tank/s. (Storage tanks are considered in your scope and should be of 20 M3 to 50 M3 capacity). Storing of water into this tank will give retention period for water and thus chlorine will effectively oxidize the organic impurities (kill bacteria and virus).  This chlorinated water is passed through Multi Media Filter with the help of Feed pump of suitable capacity to remove suspended impurities. This filter unit gives the coarse filtration. Filtered water is then passed through Activated Carbon Filter to remove excess chlorine (de-chlorination), odour, colour and turbidity due to colloidal suspended impurities and organic impurities.  De chlorinated water is then dosed with Anti Scalent Solution to avoid scale formation on the membrane. This water is further passed through 10-micron Bag Filter Followed by 5 Micron Cartridge filter to remove micron particles to avoid clogging of the RO membrane and to improve the silt density index. This water is further dosed with SMBS solution to remove residual chlorine from Water. RO Unit is complete with High Pressure Pump, Membranes with Pressure tubes, Electrical control panel and wet panel, piping with valves and all the required accessories viz., pressure switch, solenoid valve etc. Reverse Osmosis unit will reduce the dissolved Salts up to 95% of the in feed TDS. RO treated water is either adjusted for TDS by blending Filtered water passed through 0.2 Micron Cartridge Filter followed by UV OR dosed with Mineral. pH is also adjusted in case of pH below the limit to raise to 7.5.  Treated water from RO unit will be stored into SS tank of 2000 Lts capacity.  This treated water is then passed through 0.2 micron cartridge filter before it is taken for the filling. Ozonator unit producing ozone gas is installed in series at the outlet of UV System to provide residual effect of ozone to the water.

EQUIPMENT SCHEDULE


Chlorine Dosing System (Metering Pump)

To inject chlorine into feed water to inhibit the growth of bacteria and eliminate any existing bacterial contamination in the feed water.

  • ❖ Complete with 50 Lts capacity High Density Polyethylene tank.
  • ❖ LMI make High pressure chemical injection metering pump.

Raw Water Booster Pump

To boost water pressure from raw water tank and to deliver to the pretreatment at pressure and volume required.

  • ❖ SS 304 Pump of Grundfoss or equivalent, skid complete with control box, pressure gauge, check valves.

Sand Filter

To filter sand and sediment (turbidity) down to 20 microns at 2 ppm

  • ❖ Stainless Steel SS-316 tank with Praher make Austrian control valve for backwash, rinse Filter media with graded sand, pressure gauge etc.

Activated Carbon Filter

To remove taste odors, chlorine, color and other organic material from feed water prior to reverse osmosis

  • ❖ Stainless Steel SS-316 tank with Praher make Austrian control valve for backwash, rinse, 2 layers of media with granular activated carbon, pressure gauge etc.

Anti Scalent Dosing System (Metering Pump)

To inject Anti Scalent Solution into feed water to avoid scale formation on the membrane.

  • ❖ Complete with 100 Lts capacity High Density Polyethylene tank.
  • ❖ LMI make High pressure chemical injection metering pump.

5 Micron Filter

To remove micron sediment particles from raw water prior to Reverse Osmosis system to avoid clogging of membrane.

  • ❖ SS housing with Micron Bag (washable) with pressure gauge etc.

10 Micron Filter

To remove micron sediment particles from raw water prior to Reverse Osmosis system to avoid clogging of membrane.

  • ❖ SS housing with Micron Cartridges with pressure gauge etc.

Fully Automatic Reverse Osmosis unit

To purify and remove 98% of all known contaminants.

  • ❖ Fully automatic reverse osmosis system complete with High Pressure pump of Grundfoss or equivalent, high performance membranes of 40” x 40” or 80-40 long, Solenoid valve, pressure switch, Flow Indicators for reject and product water, state of the art control panel with TDS meter to continuously monitor the product water quality, Piping, Valves etc..

SMBS Dosing System (Metering Pump)

To inject SMBS Solution into feed water to remove residual Chlorine if any in water. Complete with 100 Ltrs capacity High Density Polyethylene tank. LMI make High pressure chemical injection metering pump.


SS Storage Tank for Storing Treated water

To store Reverse Osmosis permeate (product) water.

  • ❖ SS 304/316 tank of 2000 Ltr. capacity.

SS Booster pump

To feed water to down stream micron filters and UV system.

  • ❖ Stainless Steel Pump with control box, level switch interlocking, isolation valve etc.

Micron filtration units

To remove micron particles up to 0.2 Micron sizes.

  • ❖ Stainless steel micron filter housing with cartridge, pressure gauge, etc

UV Sterilizer Unit

To eliminate bacteria and Virus from Water.

  • ❖ Stainless steel housing with UV Lamps, Quartz Jacket, Ballast etc. etc

Ozonation Unit with Re pressurization Pump

To re pressurize the product water after storage and also to generate, mix and inject ozone gas into feed to filling system.

  • ❖ Corona discharge ozonation unit with re pressurization pump, water sensor safety unit, ventury injector, heater for removing moisture from silica quartz used to remove moisture from air.

Electrical Control Panel

To control all the Pumps & Electrical units

  • ❖ Mild Steel Powder Coated Electrical control Panel with TDS meter, Starters, Relays, Level Switches etc.

Wet Panel

To control Flows and Pressure of all the units of the System.

  • ❖ Panel with Flow Indicators, Pressure Gauges, Control Valves, etc.

Treated Water Quality

The approximate quality of treated water is as follows considered for design of system.


Suspended Solids Nil
Turbidity Nil
pH 7.00 to 7.5
T D S Less than 40 ppm
Total Hardness 30 ppm as CaCo3
Bacteria Coliform Nil

The above water quality is approximate assumption, We can change property of minerals/ions in water by editing the raw water in R.O. treated water.

Feed Water Conditions For R.O. Systems


Max. Temperature 40 deg. C
Free Chlorine, Bacteria, Oil Nil
Iron, Manganese.etc. Nil
Turbidity Less than 1.0 NTU


Scope of Exclusion

❖ Foundation for Equipments and any Civil Works.

❖ Power, Water and Electrifications.

❖ Raw water storage.

❖ Testing Chemicals and Facility.

❖ Testing Chemicals and Facility.